Features
- 2U horizontal rackmount; 2 L6-30P inputs; 19 outlets (16 C13, 2 C19, 1 L6-30R)
- Enables redundant-power configurations for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- Single phase 30A 208V Auto Transfer Switch / ATS Metered PDU with Solid State Switching
Product Description
Tripp Lite PDU Metered ATS 208/240V 30A 16 C13; 2 C19; 1 L6-30R 2U RM TAA - 2UHorizontal Rackmount
Specification
Brand Name | |
Brand Name | Tripp Lite |
Depth | |
Depth | 12.5" |
Environmental Certification | |
Environmental Certification | RoHS |
Environmentally Friendly | |
Environmentally Friendly | Yes |
Height | |
Height | 3.5" |
Input Receptacles | |
Input Receptacles | 2 x NEMA L6-30P |
Input Voltage | |
Input Voltage | 230 V AC |
Input Voltage Range | |
Input Voltage Range | 208 V AC - 240 V AC |
LIMITED WARRANTY | |
LIMITED WARRANTY | 2 Year |
Manufacturer | |
Manufacturer | Tripp Lite |
Manufacturer Part Number | |
Manufacturer Part Number | PDUMH30HVAT |
Manufacturer Website Address | |
http | //www.tripplite.com |
Marketing Information | |
Marketing Information | Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. |
Mounting Orientation | |
Mounting Orientation | Horizontal |
Output Receptacles | |
Output Receptacles | 1 x NEMA L6-30R |
Output Receptacles | 2 x IEC 60320 C19 |
Output Receptacles | 16 x IEC 60320 C13 |
Output Voltage | |
Output Voltage | 208 V AC |
Output Voltage | 240 V AC |
Package Contents | |
Package Contents | Metered PDUMH30HVAT 19-Outlets PDURackmount Installation BracketsInstallable Plug-retention ShelvesCable Ties |
Placement | |
Placement | Rack |
Product Model | |
Product Model | PDUMH30HVAT |
Product Name | |
Product Name | Metered PDUMH30HVAT 19-Outlets PDU |
Product Series | |
Product Series | Metered |
Product Type | |
Product Type | PDU |
Rack Height | |
Rack Height | 2U |
Weight (Approximate) | |
Weight (Approximate) | 13.80 lb |
Width | |
Width | 17.5" |
From the Manufacturer
Warranty
Extended warranties can save you hundreds, sometimes even thousands of dollars in unexpected repairs. You can contact us, or visit our store for additional details.
Delivery
Let our team co-ordinate professional delivery and installation on your new purchase. Some restrictions may apply.
Disclosures
Proposition 65 Warning for California Residents
Cancer and Reproductive Harm - P65Warnings.ca.gov
Tripp Lite PDU Metered ATS 208/240V 30A 16 C13; 2 C19; 1 L6-30R 2U RM TAA - 2UHorizontal Rackmount
Features
- 2U horizontal rackmount; 2 L6-30P inputs; 19 outlets (16 C13, 2 C19, 1 L6-30R)
- Enables redundant-power configurations for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- Single phase 30A 208V Auto Transfer Switch / ATS Metered PDU with Solid State Switching